The main function of "Electrical connection" is to complete the electrical connection from the string to combiner/inverter and to transformer.

Sequence of Cable Path and electrical connection
Users can first define cable paths and then divide strings to L1/L2 devices. Conversely, it is also possible.

Attention: If divide strings first, users must click "Relocate All" to make the combine device close to the cable trench after the cable route is drawn.
Users can also click on the "L1 devices" button, left click to select any power block, right-click to select "Relocate all L1/L2 devices".

Locate L1 devices
Location type: "No turn-back", "Shortest PV cable", and "Economic comparison".

Non turn-back and Shortest PV cable
"No turn-back" means that the cable path from strings to combiners to transformers does not turn back.
"Shortest PV cable" means the sum lengths of the PV cables from each string to the combiner is the shortest.
If a path has been drawn, priority will be given to ensuring that the combine device is placed near the path.

There are two placement locations for the Combine device:

The height of the combine device above ground refers to the distance from the center point of the combine device to the ground. The size of the combine device can be changed in the User settings.

Distance threshold: When the distance between the array and the cable path is less than this value, the array is judged to be adjacent to the cable path, and a combiner device can be placed below the array.
Economic Comparison and Selection
Compare the NPV for each position and select the best one.
NPV = NPV(yield) -NPV(cable cost)

Defining Cable Paths
The defined cable path must be a tree like structure with a unique endpoint: transformer.

Manual Drawing
Step 1 :Start drawing from the transformer.
Step 2 :Pick points from the existing transformer path and continue drawing.
Step 3 :The path must at least exceed the center of the short side of the array to ensure that the array can project onto the cable path.Ensure that each array can be horizontally connected to a suitable cable path.

Attention:The cable path should be close to the intended connected array, and the distance from the center point of the array should not exceed (0.5 times the length of the array+6 meters).

After defining the cable path, the software will automatically detect whether the array is close to the cable path.
When drawing cable paths, the TABLE key can be used to switch whether to capture orthogonality.
Importing from Layers
The cable path drawn in CAD requires:
The starting point of the cable path for each power block is located at the center of the transformer, forming a tree like structure.
Can draw the paths of all power blocks at once.

Import the above cad File, refer to "Toolkit→Synchronization with CAD".
Enter the cable drawing tool, select any power block, press F2 key, and select the correct cable path layer to complete the import.

Edit Cable Path
During the process of drawing cable paths, the right-click menu can switch to editing mode.
During the process of editing cable paths, the right-click menu can switch back to drawing mode.
In the Edit/Draw Status, you can "Check the unconnected Cable route", "Auto connect the Cable route of This block/All blocks", "Clear this block/All blocks not connected to Transformer", "Clear this block/All blocks" and "Show cable route of other blocks" in the right-click menu.

Automatic wiring
Wiring All: automatic wire all power blocks.
Wiring selected: Select the power blocks to be divided with the left mouse button, or use Ctrl + left mouse button to select multiple power blocks, and then right-click to complete the selection.
The following power block list dialog box will pop up,If the electrical connection of the power block includes L2 devices, a dialog box will pop up as shown in the following figure.
Click on the "Calculate" button corresponding to any power block to calculate the inputs.
Calculation type: Users can choose the appropriate "calculation method" based on specific project requirements.
Auto. equalization: the software will automatically adjust to ensure that the qty. of strings connected to each combine device is balanced, thereby avoiding any combine device from having too few strings connected.

After completing the above settings, the software will pop up a dialog box.

Manual wiring/manual adjustment
Click “L1 devices” or “L2 devices” to start manual wiring or adjustment.
L1 devices
Click the "L1 devices" button, users can use the left mouse button to select the power block or click on the tag in the legend at the top left of the screen, and the software will pop up the following interface.
The "exclusion method" includes 11 types: top (right), top (left), bottom (right), bottom (left), left (top), left (bottom), right (top), and right (bottom), by box selection(up/down), by box selection(left/right), reserve.
Auto. equalization: Allocate strings to L1 devices evenly.
Continuous division: A large group of strings can be selected at once, and multiple clusters will be created according to the plan at once, which can improve the efficiency of convergence division.

Mode 1 : Continuous division mode
Click “L1 devices”. The software defaults to normal mode, left-click to enter continuous mode, or switch via the right-click menu. If the number of selected strings exceeds the set value of "planned inputs", the software will automatically remove the strings according to the exclusion type selected in the previous step to ensure that the division result meets the set value.
When the selected qty. of strings can create multiple L1 combine areas, multiple L1 combine areas will be created at once, and the results will be displayed in different colors.
During the continuous division process, the lower left corner and left legend of the SketchUp interface will display the related operation prompts.

Mode 2 : Normal mode
Click “L1 devices”. The software defaults to normal mode. Left-click to select or box select some arrays, then right-click and select menu items such as creating a new device or Create multiple Combiner areas: By plan / Reset plan / Auto wiring.
If the qty. of selected strings exceeds the set value, the software will automatically remove the strings according to the exclusion type selected in the previous step.

Mode 3 : Adjust electrical connection
To adjust the electrical connection, right-click the mouse and select add to an existing device or remove from the device (but still belonging to the power block), or delete selected arrays from the pop-up menu as needed.

During the division, the legend in the upper left corner of the interface will display the division status in real time. As shown in the following figure:

L2 devices
Click on "L2 devices" and enter "Maximum inputs" and "Planned inputs" in the pop-up box.
Use the left mouse button to select or box select a certain qty. of L1 devices, then right-click. In the pop-up menu, select related operations.

Clear wiring result
Click the "Clear all" or "Clear selected "button in the interface to delete all electrical connection configuration results or those in the selected area.