Update Date: 2026-06-29
Update highlights:
1. Create terrain
Improve terrain generation and simplify algorithms
2. Create PV module
Update Module Database
3. Export to CAD
Added the function of generating viewport boundary lines and plotting according to the layout (requires updating the CAD plugin)
4. Synchronize with CAD
Add synchronous transformers, synchronous combine devices, and synchronous electrical relationship functions
Update Description:
1. Create terrain
Significantly improve the performance of reading close polylines
Create terrain interface adds elevation points layer parameters
2. Mark available/restricted area
Optimization of mark available/restricted area performance, support for closed centerline mark restriction, and support for circular area mark restriction (partial)
3. Create zones
Support merging of areas where arrays have been placed
4. Array layout
Terrace layout supports drawing multiple centerlines
5. Delete arrays
When deleting or moving/copying arrays, do not initialize the calculation of the array shadow range line to prevent lagging
6. Analyse arrays shading loss
Optimize the calculation performance of array annual shading loss (when the area occupied by the array is only a small part of the terrain, and there are a large number of obstructions)
7. Review shading
When calculating the shadow of shading object and yield, the combine devices should be included in the calculation range
8. Pairing half string
Optimize the performance and effectiveness of auto pairing for half-string arrays
9. Divide power block
Optimization of Modify Transformer No. function
Optimization of Modify Transformer capacity function
10. Electrical connections
Optimization of the Import function for LV cable route
11. View cable tool
The internal strings cables of the PV strings can be routed along the cable route
12. MV cable combine
Optimize the initialization performance of View MV cables, and optimize the performance of switching between MV electrical connection/Draw route/Edit path tools
13. Layout related to flexible racks
The flexible rack supports the setting of double bolts
14. Device hierarchy
Add the function of Export power block configuration table
Export BOM and increase BOM for each block
Optimize the performance of the Export BOM function
15. Export to AutoCAD
Added the function of marking the cable model and length of each inverter's outgoing cable in CAD (requires updating the CAD plugin)
16. Export cable list
Export settings for cable list add new template C
LV DC thick cables support single core
MV cable supports single core
17. Export to PVsyst
Optimization of the effect of simplifying terrain when exporting to PVsyst
18. Yield Simulation
Optimization of yield calculation performance (when the area occupied by the arrays is only a small part of the terrain, and there are a large number of obstructions)
19. Income calculation
Calculate IRR and Electricity price acquisition no longer require networking
20. Export report
Add Spanish templates for Voltage drop Report, Yield Report, and Feasibility Study Report
21. User settings
The number of verification points for the height above ground of the array has been increased to support 19 points
22. Candela3D Shading Object
Modify the Tree model to support multiple types of trees, and add a Lightning arrester model
Calculate the shadow of shading object to improve the performance of calculating tree shadows
Improve the performance of setting groups as barriers
23. Trench Statistics
When the cable tray does not limit thick/thin cables, the maximum number of cables per pipe is only restricted for thick cables
Add the material statistics for laying cables between half-string arrays and the internal cables between modules in the array
24. Adjust terrain
After adjusting the terrain manually - Drawing range, if there are no terrain points within the selected area, a prompt will appear asking whether to split the terrain
25. Adjust arrays and generate site leveling general plan
Add parameter for Distance threshold for adjacent arrays
The height difference of the field leveling can be set as a range value
26. Other
Decrease the probability of program loading failure after opening SketchUp
Fixed other known bugs